T5113A Network Analyzer is designed for use in the process of development, adjustment and testing of various electronic devices in industrial and laboratory facilities, including operation as a component of an automated measurement system.
Large frequency range: 300kHz to 1.3GHz
Large dynamic range: >125dB (IFBW=10Hz), 130dB typ.
Low noise level: <-120dbm ifbw="10Hz)</li">
Low trace noise: 1mdB rms (IFBW=3kHz)
High measurement speed: 125μs/point (IFBW=30kHz)
High effective directivity: >45dB
Remote Control: LAN/GPIB/USB
Very low power consumption
“One-key-test” solution
Chi tiết
Datasheet
Measurement Range
Product Name
Impedance
50Ω or 75Ω
Test port connector
N-type, female
Number of test ports
2
Frequency range
300kHz to 1.3GHz
Full CW frequency accuracy
±5×10-6
Frequency resolution
1Hz
Number of measurement points
2 to 10001
Measurement bandwidths
1Hz to 30kHz (with 1/3 step)
Dynamic range (IF bandwidth 10 Hz)
125dB, typ.130dB
Measurement Speed
Measurement time per point
150μs
Typical cycle time versus number of measurement points
Number of points
(IFBW 30kHz)
51
201
401
1601
One-path two-port calibration
(Start 300 kHz, stop 1.3 GHz)
9ms
31ms
60ms
235ms
Manufature:
TRANSCOM
Option:
1- 5301N50 High Precision, DC to 3GHz, 50Ω, N-type Calibration Kit Set
5301N50-30101 High Precision, SOL(N-f), 50Ω, DC to 3GHz
5301N50-30102 High Precision, SOL(N-m), 50Ω, DC to 3GHz
5301N50-30103 High Precision, THROUGH N(f) - N(f), 50Ω, DC to 3GHz
5301N50-30104 High Precision, THROUGH N(m) - N(m), 50Ω, DC to 3GHz
2- 5901N50 High Precision, DC to 9GHz, 50Ω, N-type Calibration Kit Set
5901N50-90001 High Precision, SHORT N(f), 50Ω, DC - 9GHz
5901N50-90003 High Precision, OPEN N(f), 50Ω, DC - 9GHz
5901N50-90005 High Precision, LOAD N(f), 50Ω, DC - 9GHz
3- 5901N50-90007 High Precision, THROUGH N(f) - N(f), 50Ω, DC - 9GHz
5901N50-90002 High Precision, SHORT N(m), 50Ω, DC - 9GHz
5901N50-90004 High Precision, OPEN N(m), 50Ω, DC - 9GHz
5901N50-90006 High Precision, LOAD N(m), 50Ω, DC - 9GHz
5901N50-90008 High Precision, THROUGH N(m) - N(m), 50Ω, DC - 9GHz
4- 5902S50 High Precision, DC to 9GHz, 50Ω, SMA Calibration Kit 5,050
5902S50-90201 High Precision, SOL(SMA-f), 50Ω, DC to 9GHz
5902S50-90202 High Precision, SOL(SMA-m), 50Ω, DC to 9GHz
5902S50-90203 High Precision, THROUGH SMA(f) - SMA(f), 50Ω, DC to 9GHz
5902S50-90204 High Precision, THROUGH SMA(m) - SMA(m), 50Ω, DC to 9GHz
5- T5_RFCAB-NmNm_18101 Test Cable - DC to 18GHz, 50Ω, N(m)-N(m) , 1m
6- T5_RFCAB-NmSMAm_18102 Test Cable - DC to 18GHz, 50Ω, N(m)-SMA(m), 1m
7- T5_RFCAB-NmNm_60101 Test Cable - DC to 6GHz, 50Ω, N(m)-N(m), VSWR<1.1, IL<1.2db span="">
8- T5_RFCAB-NmSMAm_60102 Test Cable - DC to 6GHz, 50Ω, N(m)-SMA(m), VSWR<1.1, IL<1.2db span="">
9- VNA_ATE Automated test software for VNA
10- T5_RM VNA rack mount kit
11- T5_FH VNA front handle kit